CyberPower Smart App Sinewave: Specs, Models & Replacement Batteries Canada

CyberPower Smart App Sinewave for Canada: PR and OL series UPS with SNMP, PowerPanel Business, and PowerPanel Business management. Replacement batteries, RMCARD network cards, bulk quoting.

The PFC Sinewave models below are the most-searched CyberPower units in Canada. Each row links the unit and its exact replacement battery set, both shipped from our Canadian warehouse.

ModelVAWattsForm factorReplacement battery
PR1500LCDRT2U1500 VA900 WRack/towerBattery set
PR1500LCDRTXL2U1500 VA900 WRack/tower XLBattery set
PR2200RT2UCN2200 VA2200 WRack/towerEmail us to match
PR2200RTXL2UCN2200 VA2200 WRack/tower XLBattery set
PR3000LCD3000 VA3000 WMini-towerEmail us to match

Battery life on these units: the sealed lead-acid (VRLA) packs last three to five years in normal service. Shorter runtime on the LCD, a failed self-test or a Replace Battery indicator means it is time for a new set. The swap is customer-installable in under fifteen minutes on these models.

The CyberPower Smart App Sinewave family is CyberPower’s IT-managed line, pure-sinewave UPS units with USB, serial, and (on most models) SNMP / web management slots, plus PowerPanel Business software for graceful shutdown across VMware, Hyper-V, Windows Server and Linux. We supply Smart App Sinewave across Canada from our Canadian warehouse for branch offices, small server rooms, network closets, and any environment where remote monitoring and managed shutdown matter as much as battery backup.

.svk{–svk-a:var(–cyberpower-blue, #92C83E);–svk-ink:#1a2332;–svk-mut:#6b7280;–svk-line:#e5e7eb;–svk-alt:#f8fafc;–svk-dark:#0f1419;font-family:’Inter’, system-ui, sans-serif;margin:34px 0}.svk *{box-sizing:border-box}.svk h2,.svk h3{font-family:’Inter’, system-ui, sans-serif;line-height:1.15;margin:0 0 10px;color:var(–svk-ink)}.svk h2{font-size:clamp(1.35rem,2.6vw,2rem);font-weight:800}.svk h3{font-size:1.05rem;font-weight:700}.svk p{font-size:.97rem;line-height:1.72;color:#374151;margin:0 0 12px}.svk small{display:block;font-size:.8rem;color:var(–svk-mut);line-height:1.6;margin-top:8px}.svk-stat{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin:0 0 26px}.svk-stat div{background:var(–svk-alt);border:1px solid var(–svk-line);border-radius:8px;padding:16px;text-align:center}.svk-stat b{display:block;font-family:’Inter’, system-ui, sans-serif;font-size:clamp(1.2rem,2.4vw,1.8rem);font-weight:800;color:var(–svk-a);line-height:1.1}.svk-stat span{font-family:’Inter’, system-ui, sans-serif;font-size:.72rem;font-weight:700;letter-spacing:.08em;text-transform:uppercase;color:var(–svk-mut)}.svk-dia{background:var(–svk-dark);border-radius:10px;padding:24px;margin:0 0 8px}.svk-dia svg{width:100%;height:auto;display:block}.svk-cap{font-size:.8rem;color:var(–svk-mut);text-align:center;margin:0 0 24px}.svk-tool{background:#fff;border:1px solid var(–svk-line);border-radius:10px;padding:22px;box-shadow:0 1px 3px rgba(0,0,0,.05)}.svk-tg{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-bottom:16px}.svk-tool label{display:block;font-family:’Inter’, system-ui, sans-serif;font-size:.74rem;font-weight:700;letter-spacing:.06em;text-transform:uppercase;color:var(–svk-ink);margin-bottom:5px}.svk-tool select,.svk-tool input{width:100%;padding:9px 11px;border:1px solid #cbd5e1;border-radius:6px;font-size:.95rem;color:#1f2937;background:#fff}.svk-out{background:var(–svk-dark);border-radius:8px;padding:16px 20px;color:#e5e7eb;font-size:.95rem;line-height:1.7}.svk-out b{color:var(–svk-a)}.svk-out small{color:#9ca3af}.svk-faq{border:1px solid var(–svk-line);border-radius:8px;margin-bottom:8px;background:#fff;overflow:hidden}.svk-q{font-family:’Inter’, system-ui, sans-serif;font-size:1rem;font-weight:700;color:var(–svk-ink);padding:13px 16px;cursor:pointer;display:flex;justify-content:space-between;align-items:center;gap:10px}.svk-q:hover{color:var(–svk-a)}.svk-arr{color:var(–svk-a);font-size:1.1rem;flex-shrink:0}.svk-a{font-size:.92rem;color:#4b5563;line-height:1.7;padding:0 16px 14px;display:none}.svk-faq.open .svk-a{display:block}.svk-cta{background:var(–svk-alt);border:1px solid var(–svk-line);border-left:4px solid var(–svk-a);border-radius:8px;padding:20px 24px;margin-top:24px}.svk-cta p{margin:0}@media(max-width:820px){.svk-stat,.svk-tg{grid-template-columns:1fr}}
Line interactivetopology
Rack or towerformat
24/7emergency line

How a line interactive unit protects the load

AC INPUTutility supplyAVR TRANSFORMERcorrects sags and swellsTRANSFER SWITCHutility or batteryPROTECTED LOADnetwork, workstationsBATTERYpicks up on outageBrief transfer gapwhen the utilitydrops, commonly a fewmilliseconds onpublished specs.

Line interactive: utility power passes through an AVR transformer that corrects sags and swells, and the transfer switch moves the load to battery when the utility drops.

What Smart App Sinewave adds over the CP and OR series

The desktop CP series and rack OR series cover the basics, battery backup, AVR, LCD status, USB shutdown for one host. The Smart App Sinewave line steps that up:

  • Network management slot (RMCARD205, RMCARD305): SNMPv3, web interface, syslog, email alerting, remote shutdown of multiple hosts. The same job an APC AP9630/9641 NMC does for Smart-UPS.
  • PowerPanel Business software: centralized monitoring across multiple UPS units, hypervisor integration (VMware vSphere, Hyper-V), virtual-machine-aware shutdown sequencing.
  • Pure sinewave on battery: safe for Active-PFC servers, blade chassis, network gear, storage controllers.
  • Switchable outlets: load segments you can power down individually to extend runtime for critical equipment.
  • EBM support on PR series: Extended Battery Modules for longer runtime on critical loads.

Smart App Sinewave model lines

PR Series (Smart App Sinewave, rack/tower)

Convertible rack/tower line-interactive UPS. Pure sinewave, RMCARD slot, switchable outlets, EBM-compatible. Common sizes from 1000VA up to 3000VA. Best for branch-office server racks, IT-managed small server rooms, and convergence cabinets where you might rack it today and tower it later (or vice versa).

OL Series (Smart App Online, double-conversion)

True online double-conversion. The cleanest output, zero transfer time, full input isolation. CyberPower’s pick for sensitive imaging equipment, medical lab gear, financial transaction servers, and any load where a 2-4 ms transfer is unacceptable.

Common deployment scenarios

  • Branch-office server rack: PR1500LCDRT2U or PR2200LCDRTXL2U with an RMCARD205 SNMP card, integrated into the head-office monitoring platform. Graceful shutdown of the branch hypervisor when battery hits a defined threshold.
  • Small MSP / managed-IT customer: PR-series across a portfolio of clients, all reporting back to a central PowerPanel Business install. The MSP sees every customer’s UPS battery state, mains quality, and load on one dashboard.
  • Imaging / lab equipment: OL-series online double-conversion. Zero transfer time matters when the load is a CT scanner controller, a lab analyzer, or a financial trading workstation.
  • VMware / Hyper-V cluster in a closet: PR2200 with PowerPanel Business agent on each host, orchestrating an ordered shutdown sequence so the SAN drops last.
  • Remote site (cell tower, fibre hut, surveillance head-end): OL-series with extended-battery modules for long-runtime backup ahead of generator start.

Replacement batteries for Smart App Sinewave

Battery life on PR-series sealed-lead-acid packs runs three to five years under typical conditions. EBM extended-battery modules age at the same rate, if you replace the internal pack, plan to replace the EBM at the same time so the pack pairs match for charge balance. We stock OEM-compatible replacement packs for the PR1500, PR2200, PR3000 and OL series and ship across Canada from our Canadian warehouse.

Need to order online? Browse the complete replacement battery catalog online. For PR/OL units that live in racks where the swap is awkward (deep cabinets, hot aisle), contact us for a shipped pack plus customer-side install instructions.

Smart App Sinewave network management cards

CardUse case
RMCARD205Standard SNMPv3 / web management for PR-series UPS units. Email alerts, event log, remote shutdown of one or more hosts via PowerPanel.
RMCARD305Extended-feature card for OL-series online UPS. Adds environmental sensor support (temperature, humidity, contact closure) and dual-Ethernet redundancy.
ENVIROSENSORExternal temperature + humidity probe that plugs into RMCARD305. Useful for unattended closets and remote huts.

Order or request a quote

Tell us the model (or the target load + runtime), management-card needs (SNMP card or not), and quantity, we quote within 4 business hours. For multi-site MSP rollouts, ask about bulk pricing and pre-configured RMCARD shipping.

Get a Smart App Sinewave quote: email [email protected] or call 1 (438) 800-0382. Order replacement batteries online.

Related CyberPower UPS resources

Size a unit for your load

5 to 10 min (shutdown or generator)15 to 30 min45 to 60 min
Servers, storage, controlsSwitches, access points, desktops
(function(){function r(){var w=parseFloat(document.getElementById(“svk-w”).value)||0,rt=document.getElementById(“svk-rt”).value,t=document.getElementById(“svk-top”).value,o=document.getElementById(“svk-sout”);if(w<=0){o.innerHTML="Enter the load to size a unit.";return;}var tgt=w*1.25,lad=[1000,1500,2000,3000,5000,6000,8000,10000],k=null;for(var i=0;i=tgt){k=lad[i];break;}}var topo=t===”online”?”online double conversion”:”line interactive”;if(!k){o.innerHTML=”Computed target: “+Math.round(tgt)+” W with headroom. Above the 10 kVA class the answer is three phase or parallel units, and the wiring matters as much as the box. Call us and we will scope it.Rule of thumb at unity power factor.“;return;}var ebm=rt===”5″?”internal batteries are usually enough”:rt===”20″?”plan one or two external battery modules”:”plan two to four external battery modules”;o.innerHTML=”Computed target: “+Math.round(tgt)+” W with 25 percent headroom, so look at the “+(k/1000)+” kVA class in “+topo+”. For the runtime you picked, “+ebm+”.Rule of thumb sizing at unity power factor on current platforms. Confirm nameplate draw and check the model runtime table before ordering.“;}[“svk-w”,”svk-rt”,”svk-top”].forEach(function(i){document.getElementById(i).addEventListener(“input”,r);});r();})();