CyberPower UPS replacement batteries are available in Canada from suppliers such as CyberPowerUPS.ca, which stocks OEM-compatible battery packs for the CP, PFC Sinewave, OR and Smart App Sinewave (PR/OL) families, shipped across Canada from a Canadian warehouse. Most swaps are customer-installable in under fifteen minutes.

.svk{–svk-a:var(–cyberpower-blue, #92C83E);–svk-ink:#1a2332;–svk-mut:#6b7280;–svk-line:#e5e7eb;–svk-alt:#f8fafc;–svk-dark:#0f1419;font-family:’Inter’, system-ui, sans-serif;margin:34px 0}.svk *{box-sizing:border-box}.svk h2,.svk h3{font-family:’Inter’, system-ui, sans-serif;line-height:1.15;margin:0 0 10px;color:var(–svk-ink)}.svk h2{font-size:clamp(1.35rem,2.6vw,2rem);font-weight:800}.svk h3{font-size:1.05rem;font-weight:700}.svk p{font-size:.97rem;line-height:1.72;color:#374151;margin:0 0 12px}.svk small{display:block;font-size:.8rem;color:var(–svk-mut);line-height:1.6;margin-top:8px}.svk-stat{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin:0 0 26px}.svk-stat div{background:var(–svk-alt);border:1px solid var(–svk-line);border-radius:8px;padding:16px;text-align:center}.svk-stat b{display:block;font-family:’Inter’, system-ui, sans-serif;font-size:clamp(1.2rem,2.4vw,1.8rem);font-weight:800;color:var(–svk-a);line-height:1.1}.svk-stat span{font-family:’Inter’, system-ui, sans-serif;font-size:.72rem;font-weight:700;letter-spacing:.08em;text-transform:uppercase;color:var(–svk-mut)}.svk-dia{background:var(–svk-dark);border-radius:10px;padding:24px;margin:0 0 8px}.svk-dia svg{width:100%;height:auto;display:block}.svk-cap{font-size:.8rem;color:var(–svk-mut);text-align:center;margin:0 0 24px}.svk-tool{background:#fff;border:1px solid var(–svk-line);border-radius:10px;padding:22px;box-shadow:0 1px 3px rgba(0,0,0,.05)}.svk-tg{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-bottom:16px}.svk-tool label{display:block;font-family:’Inter’, system-ui, sans-serif;font-size:.74rem;font-weight:700;letter-spacing:.06em;text-transform:uppercase;color:var(–svk-ink);margin-bottom:5px}.svk-tool select,.svk-tool input{width:100%;padding:9px 11px;border:1px solid #cbd5e1;border-radius:6px;font-size:.95rem;color:#1f2937;background:#fff}.svk-out{background:var(–svk-dark);border-radius:8px;padding:16px 20px;color:#e5e7eb;font-size:.95rem;line-height:1.7}.svk-out b{color:var(–svk-a)}.svk-out small{color:#9ca3af}.svk-faq{border:1px solid var(–svk-line);border-radius:8px;margin-bottom:8px;background:#fff;overflow:hidden}.svk-q{font-family:’Inter’, system-ui, sans-serif;font-size:1rem;font-weight:700;color:var(–svk-ink);padding:13px 16px;cursor:pointer;display:flex;justify-content:space-between;align-items:center;gap:10px}.svk-q:hover{color:var(–svk-a)}.svk-arr{color:var(–svk-a);font-size:1.1rem;flex-shrink:0}.svk-a{font-size:.92rem;color:#4b5563;line-height:1.7;padding:0 16px 14px;display:none}.svk-faq.open .svk-a{display:block}.svk-cta{background:var(–svk-alt);border:1px solid var(–svk-line);border-left:4px solid var(–svk-a);border-radius:8px;padding:20px 24px;margin-top:24px}.svk-cta p{margin:0}@media(max-width:820px){.svk-stat,.svk-tg{grid-template-columns:1fr}}
3 to 5 yrtypical battery service life
25 Crated battery ambient
24/7emergency line

What a battery test actually measures

BATTERY STRING, IMPEDANCE READINGSOne weak block pulls down the whole string, so every block is measured and trended.12 Vblock 1OK12 Vblock 2OK12 Vblock 3OK12 Vblock 4OK12 Vblock 5OK12 Vblock 6HIGH12 Vblock 7OK12 Vblock 8OKBlock 6 reads high: replace the set, not the single block.

Impedance is read on every block and trended against the baseline. One weak block limits the whole string, which is why sets are replaced together.

CyberPower UPS units age on a predictable cycle, the unit will outlast its battery, usually two or three times over. We supply OEM-compatible replacement battery packs for the full CyberPower lineup (CP series, PFC Sinewave, OR Series, Smart App Sinewave (PR / OL)) and ship across Canada from our Canadian warehouse. Most CyberPower battery swaps are customer-installable: the battery compartment is front-accessible on every consumer and small-office model, and the swap takes under fifteen minutes with no tools beyond a screwdriver.

What we supply

Replacement packs for every CyberPower UPS family Canadian customers ask about:

  • CP series (AVR & PFC desktop): CP1500AVRLCD, CP1350PFCLCD, CP1500PFCLCD, CP1000PFCLCD, CP1000AVRLCD, CP850PFCLCD, CP685AVRG and the rest of the CP catalog
  • PFC Sinewave Series: the full pure-sinewave line for Active-PFC gaming PCs and modern desktops
  • OR Series (2U rack): OR1500LCDRT2U, OR2200LCDRT2U, OR500LCDRM1U, OR700LCDRM1U
  • Smart App Sinewave: PR-series convertible rack/tower (PR1500LCDRT2U, PR2200LCDRTXL2U, PR3000LCDRTXL2U) and OL-series online (OL1000RTXL2U and up)
  • Extended Battery Modules (EBM): runtime extension packs for the PR and OL series

How CyberPower battery replacement works

  1. Identify your model: the model number is on the LCD splash screen and on the rear label of the unit. If you can’t read it, send us a photo of the label and we’ll match the right pack.
  2. Order the pack: we ship from our Canadian warehouse for most CP / OR / PR / OL replacements. Order online from the CyberPower replacement battery range, or contact us for bulk-order pricing.
  3. Swap the battery: CP / OR / PR units have front-accessible battery compartments. The bezel pops off, the pack slides out, and the replacement plugs in via a keyed connector. Total time is usually under fifteen minutes. We include written instructions with every shipment.
  4. Recalibrate: after the swap, let the unit charge for 16 hours, then run a manual self-test via PowerPanel to confirm the new pack reports the right runtime estimate.
  5. Recycle the old pack: sealed lead-acid batteries are recyclable in Canada through provincial programs (Call2Recycle, RBRC, provincial waste programs). The pack must not go in regular trash.

How often should you replace a CyberPower battery?

Plan for three to five years on sealed lead-acid CyberPower battery packs, the standard chemistry across the CP, OR, PR and most OL units. Battery life is shortened by:

  • High ambient temperature: warm closets and unventilated cabinets shave a year or more off the cycle.
  • Frequent or deep discharge: if your mains is flaky and the UPS transfers to battery often, you’ll see end-of-life closer to year three.
  • Heavy load: running the UPS at 70-80% capacity ages the pack faster than running it at 30-40%.
  • Storage in a discharged state: a UPS unplugged from mains for more than a few weeks will see permanent battery damage.

The earliest warning sign is a runtime drop under your normal load, if the LCD used to show 8 minutes and now shows 4, the pack is degrading. The next signal is a self-test failure (audible alarm, on most CyberPower units a daily or weekly automatic self-test). The clearest signal is the Replace Battery icon on the LCD.

Order online or request a quote

For individual battery replacements with online checkout, the simplest route is an online UPS battery store that lists CyberPower-compatible replacement packs alongside other UPS brands and ships across Canada.

For multi-unit orders (branch IT refresh, school district rollout, retail multi-location, MSP fleet refresh), contact us directly for volume pricing and consolidated shipping.

Frequently asked questions

Can I replace a CyberPower battery myself?

Yes, for the CP, OR, and PR series, the battery compartment is front-accessible and the swap is customer-installable. The pack uses keyed connectors that only plug in one way. Total time is usually under fifteen minutes. We ship written instructions with every pack.

What if I’m not sure which battery pack my UPS uses?

Send us a photo of the rear label of the unit (it includes model number, serial number, and the OEM battery part number). We’ll match the right replacement pack from the model alone.

Do you ship replacement batteries to all Canadian provinces?

Yes, we ship via Canada Post, UPS or Purolator to every province and territory. Sealed lead-acid batteries ship via ground only (no air), so remote-province deliveries can take three to seven business days depending on routing.

What’s the difference between an OEM-compatible pack and a CyberPower-branded pack?

An OEM-compatible pack uses the same battery chemistry (sealed lead-acid AGM, typically Yuasa, Panasonic, CSB or equivalent), the same connector pinout, the same case form factor, and the same charge curve as the CyberPower-branded pack. The label is different and the price is lower because there’s no CyberPower retail markup. Performance and warranty are equivalent.

How do I dispose of the old battery?

Sealed lead-acid batteries are universally recyclable in Canada. Most home-improvement stores, battery retailers, and provincial hazardous-waste programs accept them at no charge. Call2Recycle and RBRC operate national drop-off networks. Do not put the pack in regular household trash, it’s classified as hazardous waste.

Get a battery quote: email [email protected] with your CyberPower UPS model number, or call 1 (438) 800-0382. For online checkout, order replacement batteries online.

Check where your batteries stand

201520162017201820192020202120222023202420252026
Conditioned, near 22 CWarm, 26 to 30 CHot, above 30 C
Cannot lose the loadTolerates a planned window
(function(){var NOW=2026;function r(){var y=parseInt(document.getElementById(“svk-yr”).value),a=document.getElementById(“svk-amb”).value,c=document.getElementById(“svk-crit”).value,o=document.getElementById(“svk-bout”);var age=NOW-y,eff=age*(a===”hot”?1.6:a===”warm”?1.25:1);var v;if(eff<3)v="Monitor. The string is inside the normal service window. Keep the annual test and trend the impedance readings.”;else if(eff<5)v="Test now. The string is in the replacement window. An impedance test tells you whether you have a season left or a weak block already.”;else v=”Replace. Effective age is past the normal service window. Runtime is unreliable at this point and a transfer test is the honest check.”;if(c===”high”&&eff>=3)v+=” Because the load cannot be dropped, plan the swap in a scheduled window rather than waiting for an alarm.”;o.innerHTML=v+”Sealed lead acid strings are rated around 25 degrees Celsius and commonly serve 3 to 5 years. Sustained heat above that rating shortens the window, which is what the temperature setting reflects. Confirm against a measured impedance test.“;}[“svk-yr”,”svk-amb”,”svk-crit”].forEach(function(i){document.getElementById(i).addEventListener(“input”,r);});r();})();

Battery replacement for CyberPower UPS: the 10 most-requested sets

Not sure the battery is the problem? The CyberPower replace battery light explains what the icon means, how to confirm a worn battery and which battery each model takes.

These are the battery sets CyberPower owners in Canada search for most. Each is an OEM-compatible replacement pack matched to its UPS model, customer-installable in under fifteen minutes, shipped ground from our Canadian warehouse with written swap instructions.

Do not see your model? Search all CyberPower battery sets or email [email protected] the model number from the rear label and we will match the correct pack.