The PFC Sinewave models below are the most-searched CyberPower units in Canada. Each row links the unit and its exact replacement battery set, both shipped from our Canadian warehouse.

ModelVAWattsForm factorReplacement battery
CP1500PFCLCD1500 VA1000 WMini-towerBattery set
CP1000PFCLCD1000 VA600 WMini-towerBattery set
CP850PFCLCD850 VA510 WMini-towerBattery set
CP1350PFCLCD1350 VA810 WMini-towerBattery set

Battery life on these units: the sealed lead-acid (VRLA) packs last three to five years in normal service. Shorter runtime on the LCD, a failed self-test or a Replace Battery indicator means it is time for a new set. The swap is customer-installable in under fifteen minutes on these models.

The CyberPower PFC Sinewave Series is CyberPower’s pure-sinewave line for desktops, gaming PCs, and any device with an Active-PFC switching power supply that won’t accept a stepped-approximation waveform. We supply the family across Canada from our Canadian warehouse, new units, replacement batteries, bulk quoting for IT refresh rollouts. Best for modern gaming desktops, Mac Studio / Mac mini, small servers, NAS, and any home-office setup where a simulated-sinewave AVR unit would cause the load to disconnect on transfer.

.svk{–svk-a:var(–cyberpower-blue, #92C83E);–svk-ink:#1a2332;–svk-mut:#6b7280;–svk-line:#e5e7eb;–svk-alt:#f8fafc;–svk-dark:#0f1419;font-family:’Inter’, system-ui, sans-serif;margin:34px 0}.svk *{box-sizing:border-box}.svk h2,.svk h3{font-family:’Inter’, system-ui, sans-serif;line-height:1.15;margin:0 0 10px;color:var(–svk-ink)}.svk h2{font-size:clamp(1.35rem,2.6vw,2rem);font-weight:800}.svk h3{font-size:1.05rem;font-weight:700}.svk p{font-size:.97rem;line-height:1.72;color:#374151;margin:0 0 12px}.svk small{display:block;font-size:.8rem;color:var(–svk-mut);line-height:1.6;margin-top:8px}.svk-stat{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin:0 0 26px}.svk-stat div{background:var(–svk-alt);border:1px solid var(–svk-line);border-radius:8px;padding:16px;text-align:center}.svk-stat b{display:block;font-family:’Inter’, system-ui, sans-serif;font-size:clamp(1.2rem,2.4vw,1.8rem);font-weight:800;color:var(–svk-a);line-height:1.1}.svk-stat span{font-family:’Inter’, system-ui, sans-serif;font-size:.72rem;font-weight:700;letter-spacing:.08em;text-transform:uppercase;color:var(–svk-mut)}.svk-dia{background:var(–svk-dark);border-radius:10px;padding:24px;margin:0 0 8px}.svk-dia svg{width:100%;height:auto;display:block}.svk-cap{font-size:.8rem;color:var(–svk-mut);text-align:center;margin:0 0 24px}.svk-tool{background:#fff;border:1px solid var(–svk-line);border-radius:10px;padding:22px;box-shadow:0 1px 3px rgba(0,0,0,.05)}.svk-tg{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-bottom:16px}.svk-tool label{display:block;font-family:’Inter’, system-ui, sans-serif;font-size:.74rem;font-weight:700;letter-spacing:.06em;text-transform:uppercase;color:var(–svk-ink);margin-bottom:5px}.svk-tool select,.svk-tool input{width:100%;padding:9px 11px;border:1px solid #cbd5e1;border-radius:6px;font-size:.95rem;color:#1f2937;background:#fff}.svk-out{background:var(–svk-dark);border-radius:8px;padding:16px 20px;color:#e5e7eb;font-size:.95rem;line-height:1.7}.svk-out b{color:var(–svk-a)}.svk-out small{color:#9ca3af}.svk-faq{border:1px solid var(–svk-line);border-radius:8px;margin-bottom:8px;background:#fff;overflow:hidden}.svk-q{font-family:’Inter’, system-ui, sans-serif;font-size:1rem;font-weight:700;color:var(–svk-ink);padding:13px 16px;cursor:pointer;display:flex;justify-content:space-between;align-items:center;gap:10px}.svk-q:hover{color:var(–svk-a)}.svk-arr{color:var(–svk-a);font-size:1.1rem;flex-shrink:0}.svk-a{font-size:.92rem;color:#4b5563;line-height:1.7;padding:0 16px 14px;display:none}.svk-faq.open .svk-a{display:block}.svk-cta{background:var(–svk-alt);border:1px solid var(–svk-line);border-left:4px solid var(–svk-a);border-radius:8px;padding:20px 24px;margin-top:24px}.svk-cta p{margin:0}@media(max-width:820px){.svk-stat,.svk-tg{grid-template-columns:1fr}}
Line interactivetopology
Rack or towerformat
24/7emergency line

How a line interactive unit protects the load

AC INPUTutility supplyAVR TRANSFORMERcorrects sags and swellsTRANSFER SWITCHutility or batteryPROTECTED LOADnetwork, workstationsBATTERYpicks up on outageBrief transfer gapwhen the utilitydrops, commonly a fewmilliseconds onpublished specs.

Line interactive: utility power passes through an AVR transformer that corrects sags and swells, and the transfer switch moves the load to battery when the utility drops.

Why pure sinewave matters for modern desktops

Older switching power supplies were tolerant of a stepped-approximation (“simulated sinewave”) waveform on battery, which is what most line-interactive AVR UPS units output. Newer Active-PFC power supplies, the kind in current gaming PCs, modern Mac desktops, many small-form-factor PCs and current-gen workstations, reject that waveform and shut the load down rather than risk damage. The result is exactly what a UPS is supposed to prevent: an unexpected power loss the moment the mains drops out.

Pure-sinewave UPS units like the CyberPower PFC Sinewave family output a clean sine wave whether the unit is on mains or on battery, so an Active-PFC power supply rides through outages and brownouts the way it would on utility power.

Models in the PFC Sinewave family

  • CP1350PFCLCD: 1350VA / 810W tower. The volume seller. Mid-tower gaming PC + monitor + network gear. Eight outlets (four battery + surge, four surge-only).
  • CP1500PFCLCD: 1500VA / 1000W tower. Extra headroom for a high-wattage gaming rig, dual monitors, or a desktop plus small server/NAS. Ten outlets (five battery + surge, five surge-only).
  • CP1000PFCLCD: 1000VA / 600W tower. Right-sized for a single workstation plus monitor and modem.
  • CP850PFCLCD: 850VA / 510W compact tower. Smaller home office and entry-level gaming.

Common deployment scenarios

  • Gaming desktop with Active-PFC PSU: Corsair, Seasonic, EVGA, Be Quiet!, Thermaltake and most modern 80+ Gold/Platinum/Titanium units are all Active-PFC. A pure-sinewave UPS is mandatory; a CP1500AVRLCD will drop the PC the moment it transfers to battery.
  • Mac Studio, Mac mini M-series, iMac: Apple desktop power supplies are Active-PFC. Match with CP1000PFCLCD or CP1350PFCLCD depending on peripherals (display, Thunderbolt dock, external storage).
  • Home server / NAS: Synology DS-series, QNAP, custom TrueNAS / Unraid builds. The CP1350PFCLCD comfortably runs a 4-bay or 6-bay NAS plus a small network switch and modem with enough runtime for a graceful shutdown.
  • Workstation rendering / CAD: high-wattage GPU + multi-monitor + Wacom + external storage. CP1500PFCLCD is the right pick.
  • Small-business POS with modern receipt + payment terminal: CP1000PFCLCD or CP1350PFCLCD depending on terminal count.

Replacement batteries for the PFC Sinewave Series

Battery life on the PFC Sinewave line is typically three to five years for sealed lead-acid (longer in cool, low-load rooms; shorter in warm closets or under heavy discharge). The orange Replace Battery icon on the LCD is the clearest signal. We supply OEM-compatible replacement battery packs for every model in the family and ship across Canada with installation instructions, the battery compartment on the CP and CP-PFC units is front-accessible and most customers swap it themselves in under fifteen minutes.

Need to order replacement batteries online? Browse the complete CyberPower-compatible battery catalog online.

Common PFC Sinewave issues

SymptomLikely causeWhat to do
Orange Replace Battery LCD iconBattery end-of-lifeOrder matching CyberPower replacement battery cartridge
Runtime drops noticeably under same loadBattery degradationReplace battery; recalibrate with PowerPanel
Repeated transfers to battery during normal dayMarginal mains voltage; AVR compensatingCheck LCD voltage reading; consider electrician inspection
Unit beeps but PC stays onNormal, on-battery alarmSave work; let unit run down or restore mains

Order or request a quote

Tell us the model and quantity, plus shipping postal code, and we quote within 4 business hours. For multi-location rollouts (POS, branch offices, school computer labs), bulk pricing applies.

Get a PFC Sinewave quote: email [email protected] or call 1 (438) 800-0382. Order replacement batteries online.

Related CyberPower UPS resources

When the original cells age out, CyberPower replacement batteries are available for every PFC Sinewave model.

Replacement pack timing for PFC Sinewave models is covered in our CyberPower battery replacement guide.

When the Replace Battery icon comes on, see what the CyberPower replace battery light means and which battery each model takes.

Size a unit for your load

5 to 10 min (shutdown or generator)15 to 30 min45 to 60 min
Servers, storage, controlsSwitches, access points, desktops
(function(){function r(){var w=parseFloat(document.getElementById(“svk-w”).value)||0,rt=document.getElementById(“svk-rt”).value,t=document.getElementById(“svk-top”).value,o=document.getElementById(“svk-sout”);if(w<=0){o.innerHTML="Enter the load to size a unit.";return;}var tgt=w*1.25,lad=[1000,1500,2000,3000,5000,6000,8000,10000],k=null;for(var i=0;i=tgt){k=lad[i];break;}}var topo=t===”online”?”online double conversion”:”line interactive”;if(!k){o.innerHTML=”Computed target: “+Math.round(tgt)+” W with headroom. Above the 10 kVA class the answer is three phase or parallel units, and the wiring matters as much as the box. Call us and we will scope it.Rule of thumb at unity power factor.“;return;}var ebm=rt===”5″?”internal batteries are usually enough”:rt===”20″?”plan one or two external battery modules”:”plan two to four external battery modules”;o.innerHTML=”Computed target: “+Math.round(tgt)+” W with 25 percent headroom, so look at the “+(k/1000)+” kVA class in “+topo+”. For the runtime you picked, “+ebm+”.Rule of thumb sizing at unity power factor on current platforms. Confirm nameplate draw and check the model runtime table before ordering.“;}[“svk-w”,”svk-rt”,”svk-top”].forEach(function(i){document.getElementById(i).addEventListener(“input”,r);});r();})();